Lux and foot-candles in one minute

Lux measures illuminance: how much light falls on a surface. One lux is one lumen per square meter [1]. A foot-candle is one lumen per square foot, and one foot-candle equals 10.763 91 lux [2]. In practice, divide lux by about 10.76 to get foot-candles, or multiply foot-candles by 10.76 to get lux.

Both are photometric units. NIST explains that photometric units compensate for human visual sensitivity, unlike purely physical measures of light [3]. So a lux reading describes light as the eye would weigh it, not the total energy arriving.

Do not confuse lux with lumens. Lumens describe how much light a lamp gives out; lux describes how much of it lands where you are. The same lamp gives fewer lux on a desk that is farther away.

How much light is enough? What the guidance says

Britain’s Health and Safety Executive (HSE) publishes recommended light levels for workplaces in its guide HSG38, Lighting at work. It gives an average illuminance and a minimum measured illuminance for each kind of activity [4]. We converted its figures to foot-candles and to the zones our app Candela uses.

HSE HSG38 recommended illuminance, with our conversions
Activity (HSE)Average luxMinimum measured luxAverage in foot-candlesCandela zone for the average
Movement of people, machines and vehicles (corridors, lorry parks)2051.9Dim
Movement in hazardous areas; rough work with no detail (loading bays, excavation)50204.6Dim
Work requiring limited perception of detail (kitchens, large assembly)100509.3Dim
Work requiring perception of detail (offices, bookbinding)20010018.6Comfortable
Work requiring perception of fine detail (drawing offices, electronics assembly)50020046.5Comfortable

HSE’s own web page gives three everyday examples: a process control room lit at 300 lux, a corridor or walkway that may need only 50 lux, and studying an engineering drawing, which may need 750 lux [5].

In the United States, OSHA’s construction rule sets legal minimums in foot-candles while work is in progress. Some rows of its Table D-3: 3 foot-candles for general construction areas such as excavation and loading platforms, 5 for indoor warehouses, corridors and exitways, 10 for general construction plant and shops, and 30 for first aid stations, infirmaries and offices [6].

Worked example · checking a site office against OSHA’s minimum

  1. OSHA’s minimum for offices on a construction site is 30 foot-candles.
  2. 30 × 10.763 91 = 322.9 lux.
  3. Suppose a phone held flat on the desk reads 280 lux. 280 ÷ 10.763 91 = 26.0 foot-candles.

The reading is about 13% below the minimum. Because a phone sensor is not a calibrated meter, that is a reason to check with a proper light meter, not proof either way.

What the light sensor in your phone is

Many Android phones have an ambient light sensor near the top of the screen, though some tablets and TV boxes have none. Android’s own documentation lists its common use as “controlling screen brightness” [7]. The sensor reports the current illumination in lux, and it reports “on change”: it sends a new value when the light changes, not on a fixed clock [8].

Apps such as Candela read that same number. Candela shows it in lux, foot-candles or EV and sorts it into five zones: Dark below 20 lux, Dim from 20, Comfortable from 200, Bright from 750 and Harsh from 5,000. The reading comes from that sensor near the top of the screen, not through the camera lens, so keep that part of the phone facing the light you want to measure.

Five things a phone light sensor can’t tell you

  1. Whether the number is right. Phone light sensors are not calibrated instruments, and one phone can differ from the next. Candela lets you adjust readings by up to 30% in either direction to match a reference meter you trust, but without that meter you cannot know the error.
  2. The light on your work surface, unless you put the phone there. Illuminance is light falling on a surface. Guidance for a desk or a bench means the light at that desk or bench. Hold the phone flat, screen up, where the task is.
  3. Very bright light, beyond the sensor’s range. Every Android sensor reports a maximum range [7]. Above it, the reading may stop rising. Candela warns when a reading reaches 95% of the range the phone reports, because the true value could be higher.
  4. Color, glare and contrast. HSE notes that lighting also depends on factors such as color, contrast and glare [5]. A lux number captures none of them, and it is not a measure of color temperature.
  5. Light for plants. Lux is weighted for human eyes, not for plants. Candela does not measure PAR or PPFD, the quantities used for grow lights.

What we tested, and what we have not

These are our own test notes for Candela, from September and October 2026.

Candela checks (our tests)
TestDeviceResult
Exact values sent to the sensor: 50, 500 and 5,000 luxAndroid emulatorRead back as 50.0, 500.0 and 5,000.0
Zones at 12, 420 and 60,000 luxAndroid emulatorDark, Comfortable and Harsh, as designed
Sensor maximum rangeAndroid emulatorReported 40,000 lux, but passed 60,000 through unchanged
Live sensor in the release buildTECNO KJ5, Android 13Readings arrived; the session maximum was 847 lux
Comparison with a calibrated lux meterNone yetNot done

The emulator result is a warning in itself: the reported maximum is a figure the sensor declares, and our emulator did not enforce it. We have not yet measured where real phones stop, or how much tilting the phone changes a reading. Until we do, we treat Candela’s readings as estimates for comparing places and times, and we say so in the app.

For photographers: lux to EV

Candela also converts lux to an exposure value at ISO 100, using an incident-light constant of 250: EV = log₂(lux ÷ 2.5).

Worked example · a reading of 10,240 lux

  1. The sensor reads 10,240 lux. 10,240 ÷ 2.5 = 4,096.
  2. log₂(4,096) = 12, so the light is EV 12 at ISO 100.

EV 12 at ISO 100 matches f/5.6 at 1/125 s, which is what Candela suggests with its default f/5.6 setting. Treat it as a starting point and check your first frame.

Questions people ask

How many lux do I need for desk work?

HSE’s guide gives an average of 200 lux, and a minimum measured illuminance of 100 lux, for work that needs perception of detail, such as offices. For fine detail, such as a drawing office, it gives 500 lux.

How do I convert foot-candles to lux?

Multiply by 10.763 91. For example, 30 foot-candles is about 323 lux, and 5 foot-candles is about 54 lux.

Why do two phones show different lux in the same spot?

Their sensors and maximum ranges differ, and phone sensors are not calibrated instruments. Hold both flat in the same place; if they still differ, only a calibrated meter can say which is closer.

Can I use a phone light meter for plants?

Only for a rough comparison of brighter and darker spots. Lux is weighted for human vision, and Candela does not measure PAR or PPFD, the quantities used for grow lights.

Try it on your phone. Candela reads your phone’s light sensor in lux, foot-candles or EV, shows a 60-second trend, and asks for no permissions.

This guide explains light measurements; it is not workplace safety or legal advice. Ardesse is not affiliated with HSE, OSHA, NIST or Google.

Sources

Last reviewed 2026-11-04. Our own test notes are from our internal Candela logs, named in each row of our fact-check file.

  1. NIST Guide to the SI, Chapter 4, Table 3: lux, lx, lm/m² — read 4 Nov 2026.
  2. NIST Guide to the SI, Appendix B.8: footcandle to lux, 1.076 391 E+01 — read 4 Nov 2026.
  3. NIST: SI Redefinition, Candela — read 4 Nov 2026.
  4. HSE, HSG38 Lighting at work: average and minimum measured illuminance by activity — read 4 Nov 2026.
  5. HSE: Lighting, thermal comfort, working space, noise and vibration — read 4 Nov 2026.
  6. OSHA 29 CFR 1926.56, Illumination, Table D-3 — read 4 Nov 2026.
  7. Android Developers: Sensors Overview (TYPE_LIGHT; getMaximumRange) — read 4 Nov 2026.
  8. Android Open Source Project: Sensor types, Light (on-change, SI lux) — read 4 Nov 2026.